Layout confirmed by drawing
Provide the available installation envelope and connection positions. The final drawing should define dimensions, access clearances, inlet and outlet arrangement and the equipment support method.
A manual-discharge centrifuge configuration for an agreed equipment layout. The reference specification lists 960 L/h processing flow, 4.5 L solids capacity and a 0–80°C operating range.

The VC-30C is the custom-layout member of the 30 series. Use it where the available sump arrangement or installation space calls for a configuration review. Final dimensions depend on the agreed configuration and are confirmed in the approved drawing. Review the feasibility of each requested modification before ordering.
Provide the available installation envelope and connection positions. The final drawing should define dimensions, access clearances, inlet and outlet arrangement and the equipment support method.
Review the specifications alongside your process conditions and installation requirements. The quotation should confirm the configuration, connections and required documentation.
Review the reference specifications below. Final dimensions depend on the agreed configuration and are confirmed in the approved drawing. Confirm the final weight and electrical requirements in the quotation before ordering.
| Discharge mode | Manual solids removal |
|---|---|
| Processing flow | 960 L/h |
| Total power | 2.75 kW |
| Solids capacity | 4.5 L |
| Operating temperature | 0–80°C |
| Dimensions (L × W × H) | Custom; confirm approved drawing |
| Weight | 125 kg (reference) |
| Reference electrical supply | Three-phase 380 V |
| Inlet / outlet | DN26 / DN65 |
| Catalog fluid-volume reference | Within 1.5 tonnes; application review required |
Provide your site voltage and frequency so electrical compatibility can be confirmed before ordering.
Feed the contaminated fluid to the centrifugal separation stage, return clarified liquid to the circuit and retain separated solids for manual removal. Manual discharge means the operator must plan a solids-removal routine; this is a different arrangement from the automatic-discharge VC models.
Check feed and return positions, piping and the existing sump arrangement. Avoid assuming that the processing-flow rating establishes the time needed to reach a particular fluid-quality target.
The 4.5 L solids capacity describes the collection capacity, not a fixed time between cleaning operations. Solids generation and the condition of the deposit affect the required routine.
Stop and isolate the machine before opening the solids chamber. Follow the shutdown and cleaning procedure in the operating manual.
Describe the existing tank, obstructions and maintenance access. A custom enclosure or arrangement does not automatically change flow, separation performance or fluid compatibility.
The 125 kg weight is a reference value. Confirm final dimensions, weight, electrical options and modifications in the quotation and approved drawing.
Provide representative process conditions and the treatment result you need so the configuration can be assessed for your application.
Send a dimensioned installation sketch showing the sump, connection heights, obstructions and the space available for solids removal. Request confirmation of the proposed cabinet arrangement, support method, electrical requirements and service access.
Dimensions are customised, with a reference weight of 125 kg. Record the final dimensions and weight in the quotation and approved drawing. Confirm each requested modification individually; a custom layout does not automatically increase flow, extend the temperature range or change separation performance.
| Configuration | VC-30T | VC-30P | VC-30C |
|---|---|---|---|
| Main selection point | Temperature | Trolley layout | Custom layout |
| Temperature | 0–110°C | 0–80°C | 0–80°C |
| Processing flow | 960 L/h | 960 L/h | 960 L/h |
| Solids capacity | 4.5 L | 4.5 L | 4.5 L |
| Weight | 80 kg | 200 kg | 125 kg reference |
All three models have a rated processing flow of 960 L/h and 4.5 L solids capacity. Select around operating temperature and installation layout. For rotational speed or G-force requirements, request confirmation for the selected manual-discharge model.
Provide an installation sketch, connection positions, available floor space and service clearances. Confirm the final drawing rather than relying on the photograph alone.
State the electrical supply and operating conditions. Confirm the control interface and commissioning requirements for the quoted configuration.
Request the operating manual and maintenance instructions for the actual build. Agree the inspection routine and any site-specific requirements before commissioning.
The AI-enhanced image illustrates the equipment arrangement. Confirm the delivered configuration in the quotation and model-specific drawing.
Specify your site voltage and frequency. Confirm electrical compatibility and any required adaptation in the quotation.
Suitability depends on your fluid or vapour composition, contamination and operating conditions. Agree the treatment target and any required sample testing before ordering.
Provide process composition, operating temperature, expected loading, required treatment schedule, installation sketch and utilities. State the result you need so the configuration can be assessed against it.
Request a review of the proposed VC-30C configuration. Include the operating conditions and a sketch of the intended connection layout so the equipment and documentation requirements can be checked together.
Request a VC-30C Review