Industrial fluid management · VR Series

VR Series Solvent Vapour Recovery Unit

Solvent-vapour collection and recovery configurations with rated airflow ratings of 40, 80 and 100 m³/h. The reference configuration includes automatic load adjustment and direct-expansion cooling.

40 / 80 / 100 m³/h airflow1 / 2 / 2 L collection tanksDirect-expansion cooling
Request a Configuration Review
VR series solvent vapour recovery unit — representative catalog configuration
AI-enhanced series image. Confirm the selected size and configuration in the quotation.
VR Series · selection

Size Around the Vapour Stream and Airflow

Compare VR-40, VR-80 and VR-100 by airflow, collection-tank volume and installation requirements. Airflow is separate from solvent recovery rate; assess the recovered quantity and required outlet concentration for the actual vapour stream.

Automatic response to load

Operation adjusts automatically according to load. Confirm the control arrangement, allowable inlet conditions and commissioning requirements for the selected configuration.

Specify the complete process

Review the specifications alongside your process conditions and installation requirements. The quotation should confirm the configuration, connections and required documentation.

VR Series · specifications

Especificaciones técnicas

Review the standard specifications below. Dimensions are listed as length × width × height. Confirm the final configuration and installation dimensions in the quotation and approved drawing before ordering.

ModeloVR-40VR-80VR-100
Source modelFY-BZQ-40FY-BZQ-80FY-BZQ-100
Airflow40 m³/h80 m³/h100 m³/h
Collection tank1 L2 L2 L
Total power0.85 kW1.7 kW2.4 kW
Reference supply220 / 380 V220 / 380 V220 / 380 V
Dimensions (L × W × H), mm623 × 487 × 805580 × 580 × 1,6002,000 × 1,500 × 2,119
Cooling systemDirect expansionDirect expansionDirect expansion

Provide your site voltage and frequency so electrical compatibility can be confirmed before ordering.

VR Series · operation

Plan the Operating Arrangement

Direct-expansion cooling and diaphragm-pump liquid output are part of the reference configuration. Confirm inlet conditions, connections and the recovered-liquid destination during process review.

Define the feed

Provide the identity and composition of the stream, expected loading, temperature and operating pattern. Include any changes between production batches.

Agree the recovery target

State the intended use of the recovered liquid and the measurable quality or outlet condition required. Confirm the method used to verify the result.

Plan liquid handling

Define the receiving vessel, output connection and handling procedure. Tank volume is a storage parameter and should not be substituted for a recovery-rate specification.

VR Series · process fit

Solvent vapour collection points

State the solvent composition, airflow, temperature, concentration and source operating pattern. Review the capture arrangement and pressure conditions separately from the rated exhaust-air rating.

Confirm solvent compatibility, the required outlet condition and any hazardous-area certification for your installation. Recovery performance must be assessed for the actual inlet stream; protective controls alone do not establish hazardous-area suitability.

Provide representative process conditions and the treatment result you need so the configuration can be assessed for your application.

VR Series · comparison

Compare Configurations Before Ordering

The three sizes are listed in the specification table above. Select around the measured feed and required output conditions. The largest storage tank or highest airflow does not automatically provide the best result for an undefined solvent stream.

The VS line and VR line use separate model prefixes and different sizing references. VS lists storage volume and wet-vapour feed; VR lists airflow and collection-tank volume. Do not directly compare these values as if they measured the same process capacity.

VR Series · installation

Installation and Maintenance Review

Connections and access

Provide an installation sketch, connection positions, available floor space and service clearances. Confirm the final drawing rather than relying on the photograph alone.

Utilities and controls

State the electrical supply and operating conditions. Confirm the control interface and commissioning requirements for the quoted configuration.

Documentation and maintenance

Request the operating manual and maintenance instructions for the actual build. Agree the inspection routine and any site-specific requirements before commissioning.

Review the specified protection functions and settings for the selected configuration, including power-loss, circuit-fault, overtemperature and high-level protection. VS includes low-water protection; VR includes phase-loss and exhaust-overheat protection. Confirm any required certification separately.

VR Series · questions

Questions for Configuration Review

Is the catalog photograph the final configuration?

The AI-enhanced series image illustrates a representative configuration. Confirm the selected size and delivered arrangement in the quotation and approved drawing.

Can the electrical supply be changed?

Specify your site voltage and frequency. Confirm electrical compatibility and any required adaptation in the quotation.

How is suitability for my process assessed?

Suitability depends on your fluid or vapour composition, contamination and operating conditions. Agree the treatment target and any required sample testing before ordering.

What should I send with an enquiry?

Provide process composition, operating temperature, expected loading, required treatment schedule, installation sketch and utilities. State the result you need so the configuration can be assessed against it.

VR Series · quote

Send Your Process and Installation Requirements

Request a review of the proposed VR Series configuration. Include the operating conditions and a sketch of the intended connection layout so the equipment and documentation requirements can be checked together.

Request a VR Series Review

Review solvent vapour recovery requirements →